PumpSaver 232 INSIDER Pump Protection

 

SymCom, Inc. leads the industry in electronic motor control and protection

 

Manufacturer: SymCom

Model: 232-INSIDER (fits inside 1/3, 1/2, 3/4, and 1 hp Grundfos control box)

Product Information:

  • Protects Single-Phase Pumps from:
    • Dry well
    • Flow restrictions (dead-head)
    • Over current (jammed impeller)
    • Overvoltage
    • Undervoltage
  • Insider fits inside Grundfos control boxes, saving on enclosure costs
  • State-of-the-art pump protection
  • A calibration adjustment allows the insider to be calibrated to your specific pumping applications, thereby reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitors the incoming power for fluctuations, over current, and undercurrent. When an abnormality, such as loss of suction is detected, the Pump Saver then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the PumpSaver reactivates its output relay and turns the pump back on. By leaving the restart delay knob in the reset position, the PumpSaver will operate in manual reset mode.
  • Note: The use of flow restrictors or unusually high head pressures at the time of calibration may interfere with the detection of dead-head conditions.
  • Installation instructions included with diagram

Features:

  • Insider fits in existing control box, saving cost enclosure costs
  • Can be calibrated to specific pump / motor combina­tions and various conditions
  • Infrared communication with Informer makes diagnostics simple
  • Diagnostic LEDs indicate trip status and provide simple troubleshooting
  • Quick and easy installation
  • The restart delay can be set up to 225 minutes or to manual reset mode

Specifications:

  • 1 Phase Line Voltage (±10%) • • • •  230VAC
  • Load Range• • • • • • • • • • • • • • • •   1/3-1hp
  • Frequency• • • • • • • • • • • • • • • • •  50*/60Hz

 

  • Operating Points
  • Overload • • • • • • • • • • • • • • • • • • • •  125% of Cal. Point
  • High Voltage Reset Point • • • • • • • • • • • • • • • • • •  265
  • Low Voltage Reset Point • • • • • • • • • •• • • • • • • • • 190
  • Trip Delay Time (Overload) • • • • • • • • • • • • • • • •5 sec.
  • Trip Delay Time (Dry well) • • • • • • • • • • • • • • • • • 2 sec.**

 

  • Restart Delay Time
  • Overvoltage/Undervoltage Delay• • • • • • • • • •  5 sec.
  • All other faults (dry-well rec. timer• • • • • • • •   2-225 min.

 

  • Output Contact Rating (SPST)• • • •  1hp @115VAC (17 amps max.)

• • • •  1hp @240VAC  (17 amps max.)

 

*Note: 50 Hz will increase all delay timers by 20%

**Other trip delays and restart delays are available upon request.

Additional information

Weight .6 lbs
Dimensions 6 × 3.5 × 3.5 in